Part Number Hot Search : 
70000 X202C D1835 4511BD SHGM1430 63E6FS SM626HRR LTC1285
Product Description
Full Text Search
 

To Download DTA01C024 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Monitoring Relays Motor temperature Types DTA01, PTA01, DTA02, PTA02
Motor temperature monitoring relay Measuring ranges: PTC according to EN 44081 Remote and local alarm reset (DTA02, PTA02) Output: 8 A SPDT relay normally energized For mounting on DIN-rail in accordance with DIN/EN 50 022 (DTA01, DTA02) or plug-in module (PTA01, PTA02) * 22.5 mm Euronorm housing (DTA01, DTA02) or 36 mm plug-in module (PTA01, PTA02) * LED indication for relay and power supply ON (DTA02, PTA02) * Galvanically separated power supply DTA01, DTA02 PTA01, PTA02 * * * * *
Product Description
DTA01, DTA02, PTA01 and PTA02 are precise thermistor monitoring relays. They can be used to monitor the temperature of the coils of a motor with built-in PTC's. The alarm status of the relay can be reset by either an external contact or an internal button (DTA02, PTA02). The test button allows the simulation of the fault condition (DTA02, PTA02). The red LED indicates the alarm status.
Ordering Key
Housing Function Type Item number Output Power supply
DTA 01 C 230
Type Selection
Mounting DIN-rail Plug-in DIN-rail Plug-in Output SPST SPDT SPDT SPDT Supply: 24 VDC DTA 01 C 724 PTA 01 C 724 DTA 02 C 724 PTA 02 C 724 Supply: 24 VAC DTA 01 C 024 PTA 01 C 024 DTA 02 C 024 PTA 02 C 024 Supply: 115 VAC DTA 01 C 115 PTA 01 C 115 DTA 02 C 115 PTA 02 C 115 Supply: 230 VAC DTA 01 C 230 PTA 01 C 230 DTA 02 C 230 PTA 02 C 230
Input Specifications
DTA01, DTA02: PTA01, PTA02: Measuring ranges Max cold PTC resistance Alarm setpoint Return setpoint Short-circuit detection Measurement voltage Contact input DTA02 PTA02 Disabled Enabled Alarm reset Input (PTC) Terminals T1, T2 Terminals 5, 6 1500 3100 10% 1650 10% 0 to 10 2.5V (acc. to IEC 60034-11) Terminals Z1, Z2 Terminals 8, 9 > 10 k < 500 > 500 ms
Output Specifications
Output Rated insulation voltage Contact ratings (AgSnO2) Resistive loads AC 1 DC 12 Small inductive loads AC 15 DC 13 Mechanical life Electrical life SPST or SPDT relay 250 VAC 8 A @ 250 VAC 5 A @ 24 VDC 2.5 A @ 250 VAC 2.5 A @ 24 VDC 30 x 106 operations 105 operations (at 8 A, 250 V, cos = 1) 7200 operations/h
Operating frequency Dielectric strength 2 kVAC (rms) Dielectric voltage Rated impulse withstand volt. 4 kV (1.2/50 s)
Specifications are subject to change without notice (01.12.04)
1
DTA01, DTA02, PTA01, PTA02
Supply Specifications
Power supply Rated operational voltage through terminals: A1, A2 (DTA01, DTA02) 2, 10 (PTA01, PTA02) 724: 024: 115: 230: Dielectric voltage (1.2/50 s) Supply to input Supply to output Input to output Rated operational power AC DC Overvoltage cat. III (IEC 60664, IEC 60038)
General Specifications
Reaction time Alarm ON delay Reset delay < 150 ms (resistance rising from -20% to +20% set value) < 500 ms (resistance decreasing from +20% to -20% set value) (15 min warm-up time) 1000 ppm/C 0.5% on full-scale LED, green LED, yellow (EN 60529) IP 20 3 (DTA01, DTA02), 2 (PTA01, PTA02) -20 to 60C, R.H. < 95% -30 to 80C, R.H. < 95% 22.5 x 80 x 99.5 mm 36 x 80 x 87 mm Approx. 150g Max. 0.5 Nm acc. to IEC 60947 UL, CSA Yes Electromagnetic Compatibillity According to EN 61000-6-2 According to EN 50081-1
24 VDC 20%, insulated 24 VAC 15% 45 to 65 Hz, insulated 115 VAC 15% 45 to 65 Hz, insulated 230 VAC 15% 45 to 65 Hz, insulated DC supply AC supply 2 kV 4 kV 4 kV 4 kV 4 kV 4 kV 2.5VA 1.5W
Accuracy Temperature drift Repeatability Indication for Power supply ON Relay ON Environment Degree of protection Pollution degree Operating temperature Storage temperature Housing dimensions DIN-rail version Plug-in version Weight Screw terminals Tightening torque Approvals CE Marking EMC Immunity Emission
Mode of Operation
DTA01, DTA02, PTA01 and PTA02 monitor the resistance value of the PTC resistors connected to the terminals T1 and T2 (or 5 and 6). This value is related with their temperature (often the three coils of a motor) so to offer a prompt reaction to over temperature. Example 1 - DTA01 or PTA01 The relay operates as long as the measured resistance is below the rated value. The relay releases if the measured resistance (i.e. the temperature of the motor coils) exceeds the rated value. Example 2 - DTA02 or PTA02 The relay operates and the yellow LED is ON as long as the measured resistance is below the rated value. The relay releases and the yellow LED is OFF if the measured resistance (i.e. the temperature of the motor coils) exceeds the rated value. Provided that the resistance has dropped below the rated value (i.e. the temperature of the motor coils has returned cold), the relay operates when the interconnection between terminals Z1, Z2 or 8, 9 is interrupted or the reset button on the front of the unit is pressed.
Wiring Diagrams
L A1 T1 T2
m 14 7 A2 N (-) 11 5
L 2 4
m 3
T
T
10 N (-) 1
DTA01
PTA01
2
Specifications are subject to change without notice (01.12.04)
DTA01, DTA02, PTA01, PTA02
Wiring Diagrams (cont.)
L Z1 T1 T2 Z2 A1 12
L m 14 7 A2 N (-) 11 5 8 9 2 4
m 3
T
T
10 N (-) 1
DTA02
PTA02
Operation Diagrams
DTA01, PTA01
Power supply
DTA02, PTA02
Power supply
3100 W 1650 W
Reset contact
Relay ON
3100 W 1650 W
Relay ON
Dimensions
DIN-rail
22.5 99.5
Plug-in
94
36
90
83.5
80
63
28.5
80
28.5
63
Specifications are subject to change without notice (01.12.04)
3


▲Up To Search▲   

 
Price & Availability of DTA01C024

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X